| Customization: | Available |
|---|---|
| After-sales Service: | Support |
| Warranty: | 2 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Configuration instructions | technical parameters | use level |
| Filling form | Double guns and double system filling, and double guns are used alternately | |
| Fill with refrigerant | R290/R600a/R32/R22/R134a/R407C/R406a How many kinds of refrigerant | |
| mass flowmeter | AMF06/VIS-10-DC24 | 1set |
| Intelligent balancer | SC-160/150/70-Bipolar balancing technology | 2set |
| Fill the gun | AOP/C-6AG(Rear top rod self-sealing technology) | 1set |
| Filling joint | ZD1/4″OR 3/8″ | 1set |
| gun-barrel | 3M/set | 1set |
| pressure pickup | HUBA/MICROSENSOR | 1set |
| Supercharged pump / station | CSAXI-R4 | 1set |
| touch screen | WEINVIEW/ OMRON | 1set |
| PLC | OMRON(Japan) | 1set |
| AD/DA Conversion module | OMRON(Japan) | 1set |
| vacuum pump | CRV16D | 1set |
| vacuum gauge | INFICON/CSR-91-N | 1set |
| electric elements | Schneder / Chint | 1set |
| pneumatic component | SDPC,SMC,AIRTAC, EMC. | 1set |
| Control module + interface | OMRON(Japan ) | 1set |
| Combustible gas alarm control | OMRON(Japan ) | 1set |
| Combustion gas probe | Tan / Arian / Chuangxin | 1set |
| vacuum tube | TOXTO(Japan ) | 1set |
| high pressure connection | CSAIXI | 1set |
| Inductor chassis | CSAIXI | 1set |
| Cabinet / casters | GDF60 | 1set |
| Preset channel | 99set | / |
| working pressure | 2.0MPa-3.5MPa | / |
| Filling speed | 30g/s-60g/s | / |
| Single filling range | 5-399g | / |
| Filling accuracy | 100g≤±0.5% 100g≤±0.5% | / |
| vacuum rate | 14.4m³/h | / |
| System vacuum degree | ≤5Pa | / |